1)The following material may hinder the curing of electronic potting silicone, so please use after the test. When necessary, please clean the application areas. -Organotin compound or condensation silicone with organotin -Sulphur, sulfide and sulfur rubber materials -Amine compounds as well as contains the amine materials -Pewters solder flux 2)Deaeration the mixture in vacuum pump under 0.08 MPa for 3-5 minutes. Then the mixture could be used for pouring. 3)Please note that the thickness of the silicone affects the curing time. If the silicone used is a little thick, then the curing time will be a little linger. The temperature also affects the curing time. When in lower temperature, we suggest custmers appropriately heat the mixture to accelerate vulcanization. 4)Above electronic potting silicone should be sealed storage. The mixture should be used up to avoid causing waste. 5)Above silicone belongs to non-dangerous goods, but keep away from mouth and eyes. 6)When it gets stratified after a period of storage, please mix it evenly before usring, which does not affect the performance.